PS3200rm 2u   2kva tru 1800 watts out 19 in deep  online   in stock           3019480713      

©1993-2017 all rights reserved 1-855-252-5253

         

19" depth  2KVA in , 2u rugged :1800 WATTS OUT 19 inch deep   true-online      855-252-5253    Shallow Depth              MSDS    NSN No

 

 

Mil 461,901,167 tested and approved(tests available) true online 19"shallow depth.

optional isolation transformer if required,askus 

Shallow Depth 2kva 1,800 watt out 19" rack 19"depth,New 304 grade Stainless Steel, hot swappable battery, version of the PS3200rm2u with a recessed area in back for 6 Power output connectors or mil connectors.  And one extra battery pack, optional 12 year life of battery,hot swappable, attached for at least a 30 minute runtime in a small package 

This protects the plugs and allows room for the plugs on shallow depth 18 inch deep cabinets. The new chassis protects the power outlets.  Also located in the back is a UPS Master Bypass switch*optional).  This manually operated switch connects the input power directly to the output ports

in case of UPS catastrophic failure.                                                     3.4”H x16.9”W x19.”D    85 x 430 x 483mm

 The unit also has an easy access front door for replacing the battery pack.  

A 230V version of this unit is the PS3200irm2uSS.

Double Conversion true online type 2KVA UPS, external battery connector

Can be wired for Delta power or conventional power    

Dual pole circuit breakers for Delta power on your ship  with new 461 filters,100bt  ethernet also isolation,shipboard

We can ruggedize this unit to meet many MIL specs       

True online style UPS allows generators to  50/60hz without affecting your equipment.

Smart UPS tests itself and batteries periodically –alarms to advise it’s time to replace the cells

Auto restart after a full run upon utility restoration

Cold Start capable- it will become an AC power source if you need it.

Hot swappable batteries – Battery door behind front panel

optional manual bypass builtin

Output Power Capacity 1800 Watts / 2000 VA

Nominal Output Voltage 110v, 115v, 120V (std.), 127V adjustable via software ± 3%

Output Voltage Distortion Less than 3% THD at full linear load; <5% into non linear load /C factor 3:1

Output Frequency (sync to mains) or select a frequency via software- Waveform Type Sine wave

Mounting rails included for rack mounting

Built in Dynamic Bypass switches input directly to output if an overload or UPS failure should occur- (sync to mains mode only).  The optional Master Bypass is a manual switch that can be used in case even the Dynamic Bypass were to fail. option 

Emergency Power OFF contacts are located on rear of unit.  Short the contacts with a low current  switch and the UPS output is disabled

 

Output Connections (standard)

shipboard power-dual pole circuit breaker

(6) NEMA 5-20R or Military Spec ms31xx or 34xx optional

Output Overload 200% capacity for 2 seconds

Output Overload 150% capacity for 50 seconds

 

Input

Nominal Input Voltage 120V (230VAC i model available)

Input Frequency 40/70 Hz

Input Cord 10 ft. NEMA L5-20P  or Military Spec

 

Input voltage range for main operations 84 - 140V (30% load)

Input voltage range for mains operation 102 - 140V (+90% load)

Transfer Time 0 ms- Inverter is always online

Batteries & Runtime

AGM Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leakproof or hi-temp long/life batteries optional

Typical recharge time 3 hours to 90% after full run

Replacement Battery PSRBC3203 (high temperature long life batteries available for this unit-PSrbc3203H)

Battery capacity Volt amp hour 432 VA/hr

Typical Backup Time at Full Load 4.0 minutes (1800 Watts)

Typical Backup Time at Half Load 10.5 minutes (900 Watts)

Typical Backup Time at 600 Watts= 20 minutes

Runtime with 1 additional 2u battery Cabinet 19.7”deep (58 lb) PS3203rm2uBP

Typical Backup Time at Full Load 18 minutes (1800 Watts)

Typical Backup Time at Half Load 34 minutes (900 Watts)

Typical Backup Time at 600 Watts= 54 minutes

Typical Backup Time =30 minutes @1100 Watts

Battery capacity Volt amp hour 864 VA/hr

Up to 4 additional 2u battery cabinets may be daisy chained to main unit.

PS3203rm2uBP uses circuit breaker for safety – not a fuse.

 

Battery Upgrades:  All Powerstar units may be upgraded with either High temperature rated batteries or Premium Long Life High temperature rated batteries.

Long life rated 8-10 year @25°C

 -15 to +50 °C charge rated and -20 to +60 °C discharge rating- order  2 sets PSRBC3203H for 2u extended Battery cabinet PS3203rm2uBP.

 

Interface Port(s)

USB and 8 pin terminal block (no DB9) standard and available SmartSlot for optional SNMP Ethernet Network card (PS9059)- Use Multilink software 10/100 based (if supplied) or SNMP software to communicate with UPS and capture alarms with USB or Ethernet.

8 pin terminal block – Any mode Shutdown (immediate) and Battery Mode Shutdown (2 minute) inputs.

 Also Battery Mode indicator and Low Battery indicator dry contacts (30ma max.).

The purpose of Any Mode Shutdown is to shut down the UPS output by turning off the rectifier, inverter and bypass so that there is no power to the loads.  Any Mode Shutdown can be operated locally and remotely, as described as follows:

• Any Mode Shutdown can be performed by shorting Pin1 and Pin2 with external switch (not supplied)

• Battery mode Shutdown can be performed by shorting Pin3 and Pin4 with external switch (not supplied). A battery shutdown signal will not cause an immediate shutdown. It will start a 2 minute shutdown timer. This timer cannot be stopped once triggered. If utility power returns during this countdown, the Liebert GXT3 will still shut down and must remain shut down for 10 seconds. Whether the UPS turns back on when the power is restored depends on the auto-restart setting.

Control panel

LED status display with 5 load indicators and 5 battery bar-charge level indicators

Also On Line LED: On Battery: Replace Battery: Bypass enabled and Overload Indicator LEDs

Audible Alarm -Alarm when on battery: distinctive low battery alarm: on bypass

 

Protection

The PS3200 has surge protection and filters that protect the connected load from power surges, including 461 filters from Captor

Electromagnetic interference (EMI) and radio frequency interference (RFI). These features can minimize

any surges or interference present in the utility power. The filters also prevent surges or interference

generated by the UPS from adversely affecting devices connected on the same branch. Surge immunity IEC 62040-2 2nd Ed. 

Input Protection

The UPS has built-in protection against under voltage, over current, and over voltage conditions including low-energy lightning surges, introduced on the primary AC source.  The 120 and 208 VAC models can sustain input surges without damage per criteria listed in ANSI C62.41 Cat A Lev3. The 230 VAC UPS can sustain input surges without damage per criteria listed in EN61000-4-5.

 

Dimensions

Maximum Height 3.4 inches (133 mm)

Maximum Width 16.9 inches (483 mm) for 19” rack mounting

Maximum Depth right side of cabinet  18.5 inches  (470 mm) or 19” (483mm) with MB switch

Maximum Depth on Left side of cabinet 16.5” (420 mm)- power outlet side

Rack Height 2U

Net Weight 55.00 lbs. (25 kg) Shipping Weight 65.00 lbs. (29 kg)

Shipping Height 10.6 inches (270 mm) 24.00 inches (610 mm) Depth 26 inches (650 mm)

UPS Color Gleaming Stainless Steel with Brushed Aluminum front panel.

 Note:  Front panel can be painted to your spec.

 

Operating Environment

32 - 104 °F (0 - 40 °C)  (battery dependant) Increase this range to -20 +60 °C with Powerstar Premium battery

Operating Relative Humidity 0 - 95% non condensing (add conformal coating optional)

Operating Elevation 0-10000 feet (0-3000 meters)

Storage Temperature 5 - 113 °F (-15 - 45 °C)

Storage Relative Humidity 0 - 95%

Storage Elevation 0-50000 feet (0-15000 meters)

Audible noise at 1 meter from front surface of unit <43 dBA , rear <46 dBA

Online Thermal Dissipation-375 BTU /h

Standards Mother board manufactured in ISO 9001:2008 facility.

120VAC models UL Standard 1778, u-UL CSA 22.2, No. 107.1 ANSI C62.41 Cat A Level 3 IEC 61000-3-2 EN 62040-2 EN61000-4-2 EN61000-4-3EN61000-4-4 EN61000-4-5 EN61000-4-6 FCC Part 15, Class A ISTA Procedure 1A RoHs Compliant

230 Volt Units    (PS3200rm2ui)

EN 62040-1:2008 CE compliance mark EN50091-1-1 EN50091-2, Class B EN50082-1 EN 62040-2 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-3-2  ISTA Procedure 1A RoHs Compliant WEEE Compliant

 

Designed to be compliant with Mil Std 1399-300A and can be built to meet 810F shock and temperature specifications. mil 461 approved Also can be built to Mil 901D grade B. also 461 compatibility (test reports available)  We also have Military 901D grade A units available.  Contact us.

 

2 year warranty on parts and Labor                                          Description: Description: Description: PS3200rm2uSS top Trimmed.JPG